Main line branch terminal block for meter connection area

Main line branch terminals for Din rails are suitable for the internal installation of electric meter cabinets. The narrow and finger-safe branch terminal with a construction width of 17.8 mm corresponds to one subdistribution unit ("TE"). Contact-safe product variants from 1-pole to 5-pole can be flexibly configured or ordered directly.

Thanks to the special coating of the brass body, copper conductors and aluminum conductors can be connected in the main line branch terminal. Approvals according to VDE, UL and IEC enable use in further industrial sectors and international markets.

Flexible installation

Main line branch terminal (HLAK 25 and HLAK 35) on DIN rail

The main line branch terminals can be installed horizontally and vertically on the DIN rail thanks to the special mounting foot.

Latching lugs on the sides of the main line branch terminal blocks allow them to latch together. Additional stability and a distribution of the occurring mechanical forces can thus be distributed over the entire terminal rail and mounting rail.

Branch terminals in different colors

Main line branch terminal (HLAK 25 and HLAK 35) in various colors

Different color variants for the respective potential are available for clear wiring of the main line branch terminals. For the three phases black, brown and gray. Blue for the neutral conductor, and green for the ground conductor.

Connection of copper and aluminum cable

HLAK 25 and HLAK 35 (main line branch terminal) Wire connection

The compact brass core of the main line branch terminals with its special coating enables the connection of round and sector-shaped copper and aluminum wires. The screw drive with fine thread facilitates the transmission of high torques and the turned screw head ensures evenly distributed forces on the conductor.

DIN VDE 0603-3-1 and VDE 0603-3-1 for the wiring of meter cabinets with branch terminals

VDE approval for HLAK 25, HLAK 35 and HLAK 70 (main line branch terminal)

The main line branch terminals meet the more stringent standard requirements. The requirements for the branch terminals relate, for example, to a dielectric strength of 3000 volts or an increased CTI value for creepage resistance.

The corrosion protection for the steel screws used for the main line branch terminals is verified with the certificate. Standard-compliant and finger-safe wiring of small distribution boards for house and building installation technology can be realized easily and safely thanks to the main line branch terminals.

Product overview of our main line branch terminals

HLAK 25 - WPD 101 2X25/2X16

HLAK 25 - Variant of a main line branch terminal block
  • Versions of 1-pole, 3-pole, 4-pole and 5-pole
  • Connection of 2x16 mm² and 2x25 mm²
  • Installation on DIN rail and mounting plate
  • Available in five colors

HLAK 35 - WPD 102 2X35/2X25 GY

HLAK 35 - Variant of a main line branch terminal block
  • Versions of 1-pole and 2-pole
  • Connection of 2x25 mm² and 2x35 mm²
  • Installation on DIN rail and mounting plate
  • Available in five colors

HLAK 70 - WPD 103 2X70/2X50 GY

HLAK 70 - Variant of a main line branch terminal block
  • Connection of 2x70 mm² and 2x50 mm²
  • Installation on DIN rail and mounting plate
  • Available in five colors

Product features main line branch terminal